Battery Electrolytes
LCO/Gr
Performance Metrics
1. Cycling Performance (25°C):
1C charge / 1C discharge, 300–800 cycles
Capacity retention ≥80%
2. High-Temperature Storage Stability (60°C):
7-day full-charge storage
Volume expansion ≤5%
3. High-Temperature Cycling (45°C):
1C charge / 1C discharge, 300–500 cycles
Capacity retention ≥80%
4. Low-Temperature Performance (-20°C):
0.2C discharge
Capacity retention ≥60%
5. Rate Capability:
Continuous discharge: ≥60C
Instantaneous pulse discharge: 130C